ABS Brymar Floors and Kontrad LLP together are able to offer the full range of services ranging from laser levelling of Type 1 material to achieve tight tolerances through to the design of fully piled ground floor slabs.

ABS Brymar Floors can offer a full service from assisting in the advice of sub-base preparation right through to plate bearing tests prior to concrete pouring.

Utilising the latest techniques in Laser dozer levelling we are able to level areas up to 5,000 m² in a day to a tolerance of + / - 5mm.

In order to achieve the most accurate results possible it is recommended by Kontrad LLP, that the sub-base to be tested should have been levelled and rolled extensively to eliminate any heaving and rutting prior to any testing.

The building should be as weathertight as possible with the ground dry to prevent misleading results. The Plate Bearing Test is then carried out on the finished sub-base.

Plate Bearing Tests are carried out in accordance with BS 5930.

Offering a wealth of in-house experience in Geotechnical Engineering and methods of ground improvement techniques we are able to offer advice on all forms of slab construction.




Plate Bearing Test Equipment
Plate Bearing Test Equipment



Click the Above Image to see larger Version